Sign In | Join Free | My burrillandco.com
Home > Lactoscan Milk Analyzer >

Lincomycin+Macrolide+Quinolone+Erythromycin Combo Test Strip Used In Raw Milk Powder Pasteurized Milk

Beijing HiYi Technology Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Lincomycin+Macrolide+Quinolone+Erythromycin Combo Test Strip Used In Raw Milk Powder Pasteurized Milk from wholesalers
     
    Buy cheap Lincomycin+Macrolide+Quinolone+Erythromycin Combo Test Strip Used In Raw Milk Powder Pasteurized Milk from wholesalers
    • Buy cheap Lincomycin+Macrolide+Quinolone+Erythromycin Combo Test Strip Used In Raw Milk Powder Pasteurized Milk from wholesalers
    • Buy cheap Lincomycin+Macrolide+Quinolone+Erythromycin Combo Test Strip Used In Raw Milk Powder Pasteurized Milk from wholesalers

    Lincomycin+Macrolide+Quinolone+Erythromycin Combo Test Strip Used In Raw Milk Powder Pasteurized Milk

    Ask Lasest Price
    Brand Name : HiYi
    Certification : CE
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    • Product Details
    • Company Profile

    Lincomycin+Macrolide+Quinolone+Erythromycin Combo Test Strip Used In Raw Milk Powder Pasteurized Milk


    Lincomycin+Macrolides+Quinolone+Erythromycin Combo Test Strip


    OVERVIEW

    Lincomycin inhibits bacterial protein synthesis and has antibacterial effects on most gram-positive bacteria and some anaerobic gram-negative bacteria. It mainly acts on anaerobic bacteria and gram-positive cocci.
    Macrolides are a class of antibiotics with Macrocyclic lactone. Macrolide potential groups and sugar derivatives are connected by glycoside bonds to form macromolecular antibiotics. It is a class of weakly alkaline antibiotics produced by Streptomyces.
    Quinolones drugs refer to synthetic antibacterial drugs containing 4-quinolones nucleus. They are quiescent fungicides with broad antibacterial spectrum.
    Erythromycin is produced by streptomycin and is a macrolide antibiotic. Its free base is for oral use, and its lactobionate is for injection.


    The detriment of Lincomycin, Macrolides, Quinolone and Erythromycin

    Some antibiotics used in livestock, poultry and aquaculture disease prevention and feed additives will be absorbed or transformed in the organism and eliminated from the body in the form of metabolites. At the same time, a large part (about 85%) will be excluded from the body in the form of prototype drugs and directly enter the environment.
    The use of antibiotics will cause pathogenic microorganisms to develop drug resistance, making the effective dose of antibiotics to kill bacteria continue to increase.



    Importance of Lincomycin Macrolides Quinolone Erythromycin Combo Test

    Lincomycin Macrolides Quinolone Erythromycin Combo Test can help manufacturers, regulatory agencies, and the public monitor product quality and help humans keep their health.



    FEATURES & BENEFITS

    Lincomycin+Macrolides+Quinolone+Erythromycin Combo Test

    4 Sensor Kit, rapid to detect four types antibiotics residues in milk and dairy product by using colloidal gold immune-chromatography technology. As soon as 7-10 minutes to results.


    Detection Method of Lincomycin Macrolides Quinolone Erythromycin Combo Test

    Lincomycin Macrolides Quinolone Erythromycin Combo Test is a colloidal gold immune-chromatography assay that detects Lincomycin, Macrolides, Quinolone and Erythromycin in raw milk, milk powder, pasteurized milk and meets EU MRL. This kit can be applied for on-site rapid testing by various departments.


    Materials for Beta-lactam Tetracycline Streptomycin Chloramphenicol Combo Test

    1. Sample Tube

    2. Pipette & Pipette Tip

    3. Well-Plate


    Features of Beta-lactam Tetracycline Streptomycin Chloramphenicol Combo Test

    1. 8min reading results

    2. Detection limits respond to EU and US FDA norms

    3. Single test for every target sample

    4. Neither professionals nor equipment required

    5. Eyes interpretation or quantitative measurement, suitable for lab and field use

    6. Room temperature storage

    7. Non-toxic and harmless


    Lincomycin Macrolides Quinolone Erythromycin Combo Test Operation Steps

    1. Add 200ul milk into a well, then pipet up and down for 10 times to completely mix the sample with the reagent in the well.
    2. Then incubate for 3min.
    3. Insert the test strip into the micro-well with the
    sample pad fully dipped.
    4. After 5 minutes, read the results.



    SPECIFICATION

    Spicifications

    1. Specificity

    Not cross-react with macrolides, trimethoprim, sulfonamides drugs, etc.
    2. Limit of Detection
    Refer to instruction.

    Storage & Shelf-Life
    At 2~8℃ out of sunlight, 12 months

    Compolents (96T / box)
    Instruction 1
    Tube 12

    Equipments (Option)
    Timer
    Incubator
    Mini Pipette(200μL)
    Tips for mini pipette
    Reader


    APPLICATION

    For raw milk, whole milk powder, Pasteurized milk.


    Quality Lincomycin+Macrolide+Quinolone+Erythromycin Combo Test Strip Used In Raw Milk Powder Pasteurized Milk for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing HiYi Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)