    TU5200 Laboratory Laser Turbidimeter Without RFID EPA Version

    Ask Lasest Price
    Brand Name : HiYi
    Model Number : TU5200
    Certification : CE
    Supply Ability : 1000 set/month
    Delivery Time : 3-7 days
    • Product Details
    • Company Profile

    TU5200 Laboratory Laser Turbidimeter Without RFID EPA Version

    TU5200 Laboratory Laser Turbidimeter


    OVERVIEW

    The platform employs a patented optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability from test to test. For the first time you will be able to remove the uncertainty of which measurement to trust, thanks to identical 360° x 90° Detection Technology in both instruments. The TU5 Series dramatically reduces the time needed to get a turbidity measurement you can rely on. The TU5200 Lab Turbidimeter, with the 360° x 90° Detection Technology, sees more of your sample meaning you no longer have to apply silicone oil to your vial and index to ensure an accurate reading. In addition, you can have confidence that you will get consistent results in the lab, from operator to operator, since the impact of small interferences is minimized due to the collection of light at 360°.


    FEATURES

    Groundbreaking 360° x 90° Detection™ Technology:
    The TU5 Series employs a patented optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability from test to test.


    Matching lab and online results:
    For the first time you will be able to remove the uncertainty of which measurement to trust, thanks to identical 360° x 90° Detection™ Technology in both instruments.


    Everything about turbidity – faster:
    The TU5 Series dramatically reduces the time needed to get a turbidity measurement you can rely on, with 98% less online sample surface area to clean, sealed vials for calibration, and the elimination of the need for indexing and silicone oil in the lab. Not to mention, a smaller online sample volume means you will detect events almost immediately.


    SPECIFICATION

    Loadi
    Accuracy±2 % plus 0.01 NTU from 0 - 40 NTU;
    ±10 % of reading from 40 - 1000 NTU based on Formazin primary standard (at 25 °C)
    Calibration MethodFor Formazin and Stablcal:
    20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for full range

    Custom calibration for up to 6-point calibrations

    Degrees 0 - 100 mg/L
    SDVB 0 - 1000 NTU
    CertificationsCE compliant
    US FDA accession number: 1420493-000 EPA version, 1420492-000 ISO version
    Complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50)
    Australian ACMA Marking
    CommunicationLink2sc
    Dimensions (H x W x D)195 mm x 409 mm x 278 mm
    Display7" WVGA (800 x 480) color TFT-LCD with touch screen
    Enclosure ConstructionPC/ABS Blend Plastic
    Light SourceClass 2 laser product, with embedded 650 nm (EPA 0.43 mW) or Class 1 laser product, with embedded 850 nm (ISO), max. 0.55 mW (complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50)
    ModelTU5200 EPA
    Operating Humidity80 % at 30 °C (non condensing)
    Operating Temperature Range10 - 40 °C
    Power Requirements (Hz)50/60 Hz
    Power Requirements (Voltage)100 - 240 VAC
    RangeEPA:
    0 - 700 NTU / FNU / TE/F / FTU
    0 - 100 mg/L
    0 - 175 EBC

    ISO:
    0 - 1000 NTU / FNU / TE/F / FTU
    0 - 100 mg/L
    0 - 250 EBC
    RegulatoryEPA
    Repeatability<40 NTU: Better than 1% of reading or ±0.002 NTU on Formazin at 25 °C (77 °F), whichever is greater
    >40 NTU: Better than 3.5% of reading on Formazin at 25 °C (77 °F)
    Resolution0.0001 NTU / FNU / TE/F / FTU / EBC / mg/L
    Response TimeSignal averaging off: 7 seconds
    Signal averaging on: 10 seconds (when averaging time is 5 seconds)
    Sample Temperature4 - 70 °C
    Source Lamp650 nm Class 2 Laser
    Storage Conditions-30 - 60 °C (-22 - 140 °F)
    Stray Light<10 mNTU
    UnitsNTU, FNU, TE/F, FTU, EBC;

    mg/L if calibrated with Degrees calibration curve
    What's included?TU5200 benchtop turbidimeter, user manual, Stablcal kit (10, 20 and 600 NTU), 2 sample vials, power supply, dust cover, vial stand